2 results
Near-infrared spectroscopy for prediction of extubation success after neonatal cardiac surgery
- Eleanor A. Gradidge, Lisa M. Grimaldi, Katherine Cashen, Keshava M. N. Gowda, Kurt D. Piggott, Michael Wilhelm, John M. Costello, Christopher W. Mastropietro
-
- Journal:
- Cardiology in the Young / Volume 29 / Issue 6 / June 2019
- Published online by Cambridge University Press:
- 06 June 2019, pp. 787-792
-
- Article
- Export citation
-
Introduction:
Reliable predictors of extubation readiness are needed and may reduce morbidity related to extubation failure. We aimed to examine the relationship between changes in pre-extubation near-infrared spectroscopy measurements from baseline and extubation outcomes after neonatal cardiac surgery.
Materials and Methods:In this retrospective cross-sectional multi-centre study, a secondary analysis of prospectively collected data from neonates who underwent cardiac surgery at seven tertiary-care children’s hospitals in 2015 was performed. Extubation failure was defined as need for re-intubation within 72 hours of the first planned extubation attempt. Near-infrared spectroscopy measurements obtained before surgery and before extubation in patients who failed extubation were compared to those of patients who extubated successfully using t-tests.
Results:Near-infrared spectroscopy measurements were available for 159 neonates, including 52 with single ventricle physiology. Median age at surgery was 6 days (range: 1–29 days). A total of 15 patients (9.4 %) failed extubation. Baseline cerebral and renal near-infrared spectroscopy measurements were not statistically different between those who were successfully extubated and those who failed, but pre-extubation cerebral and renal values were significantly higher in neonates who extubated successfully. An increase from baseline to time of extubation values in cerebral oximetry saturation by ≥ 5 % had a positive predictive value for extubation success of 98.6 % (95%CI: 91.1–99.8 %).
Conclusion:Pre-extubation cerebral near-infrared spectroscopy measurements, when compared to baseline, were significantly associated with extubation outcomes. These findings demonstrate the potential of this tool as a valuable adjunct in assessing extubation readiness after paediatric cardiac surgery and warrant further evaluation in a larger prospective study.
Safety of tracheal intubation in the presence of cardiac disease in paediatric ICUs
- Eleanor A. Gradidge, Adnan Bakar, David Tellez, Michael Ruppe, Sarah Tallent, Geoffrey Bird, Natasha Lavin, Anthony Lee, Vinay Nadkarni, Michelle Adu-Darko, Jesse Bain, Katherine Biagas, Aline Branca, Ryan K. Breuer, Calvin Brown III, Kris Bysani, Guillaume Emeriaud, Sandeep Gangadharan, John S. Giuliano, Jr, Joy D. Howell, Conrad Krawiec, Jan Hau Lee, Simon Li, Keith Meyer, Michael Miksa, Natalie Napolitano, Sholeen Nett, Gabrielle Nuthall, Alberto Orioles, Erin B. Owen, Margaret M. Parker, Simon Parsons, Lee A. Polikoff, Kyle Rehder, Osamu Saito, Ron C. Sanders, Jr, Asha Shenoi, Dennis W. Simon, Peter W. Skippen, Keiko Tarquinio, Anne Thompson, Iris Toedt-Pingel, Karen Walson, Akira Nishisaki, For National Emergency Airway Registry for Children (NEARKIDS) Investigators and Pediatric Acute Lung Injury and Sepsis Investigators (PALISI)
-
- Journal:
- Cardiology in the Young / Volume 28 / Issue 7 / July 2018
- Published online by Cambridge University Press:
- 25 April 2018, pp. 928-937
-
- Article
- Export citation
-
Introduction
Children with CHD and acquired heart disease have unique, high-risk physiology. They may have a higher risk of adverse tracheal-intubation-associated events, as compared with children with non-cardiac disease.
Materials and methodsWe sought to evaluate the occurrence of adverse tracheal-intubation-associated events in children with cardiac disease compared to children with non-cardiac disease. A retrospective analysis of tracheal intubations from 38 international paediatric ICUs was performed using the National Emergency Airway Registry for Children (NEAR4KIDS) quality improvement registry. The primary outcome was the occurrence of any tracheal-intubation-associated event. Secondary outcomes included the occurrence of severe tracheal-intubation-associated events, multiple intubation attempts, and oxygen desaturation.
ResultsA total of 8851 intubations were reported between July, 2012 and March, 2016. Cardiac patients were younger, more likely to have haemodynamic instability, and less likely to have respiratory failure as an indication. The overall frequency of tracheal-intubation-associated events was not different (cardiac: 17% versus non-cardiac: 16%, p=0.13), nor was the rate of severe tracheal-intubation-associated events (cardiac: 7% versus non-cardiac: 6%, p=0.11). Tracheal-intubation-associated cardiac arrest occurred more often in cardiac patients (2.80 versus 1.28%; p<0.001), even after adjusting for patient and provider differences (adjusted odds ratio 1.79; p=0.03). Multiple intubation attempts occurred less often in cardiac patients (p=0.04), and oxygen desaturations occurred more often, even after excluding patients with cyanotic heart disease.
ConclusionsThe overall incidence of adverse tracheal-intubation-associated events in cardiac patients was not different from that in non-cardiac patients. However, the presence of a cardiac diagnosis was associated with a higher occurrence of both tracheal-intubation-associated cardiac arrest and oxygen desaturation.